Godrej Fridge PCB Blink Error Code

If your Godrej single door fridge is showing a blinking PCB error code, it means the control board has detected a system fault. Each blink pattern represents a specific issue. Refer to the error code table above to identify the exact fault and troubleshoot accordingly.

BlinkConditionPossible Faults
On for 1sec when given power
supply
Power OnNo fault
1Other Fault (EEPROM fault/ Reverse
Connection Problem
PCB failure or Supply
connections reversed
2AC Input Voltage FaultVoltage below 110V or
above 275V
3Compressor Open FaultCompressor winding
open or Supply from
compressor to PCB
open or PCB fault
4Compressor Start-Up FaultPCB, Compressor or
Sealed system fault
5Compressor Break-In FaultPCB, Compressor or
Sealed system fault
6IPM over temperature faultPCB fault
7RPM variation faultPCB, Compressor or
Sealed system fault
8Earth Leakage FaultCompressor Ground, if
post 8 blink if PCB goes
to 4 Blink then PCB
could be faulty
9FC Temperature Sensor faultDefrost Sensor not
connected or PCB issue
Blinks at 1sec rateSelf-test ModeNo Fault