Haier Fridge PCB Blink Error Code

If your Haier fridge is displaying a blinking PCB error code, it indicates that the main control board has detected a fault. Each blink pattern corresponds to a specific issue within the system. Check the error code table above to identify the problem and proceed with the appropriate troubleshooting steps.

BlinkMeaningSolution
led not workingDelay startwaiting 10 minute
3OK, no issueWhen power on ,will flash 3 times for self checking, this
is normally ,no issue.
6Under voltage
Voltage too low
check FG machine power cord input voltage, when
voltage less 100V, will show the error code.
Suggestion install stabilizer;
7Over voltage Voltage
too high
check FG machine power cord input voltage, when
voltage more than 300V, will show the error code.
Suggestion install stabilizer;
9Compressor issue or
inverter PCB issue;
1.check compressor resistance between U&V, U&W,
V&W, normally each resistance should be the same, if
any one has no resistance ,compressor issue;

2.check
inverter PCB with compressor connector any loose?

3.if no issue ,change inverter pcb
10inverter PCB issuechange inverter PCB
12Inverter PCB issuechange inverter PCB

2. Error Codes All Model Ref.

Ref. Service Bulletin

Leave a Reply