IFB Split Inverter AC Error Code List

Fault typeDigital display (LED)
Indoor unit/ outdoor unit communication faultE0
Indoor room temp. sensor (IRT)E1
Indoor pipe temp. sensor (IPT)E2
Outdoor pipe temp. sensor (OPT)E3
System abnormalE4
Indoor fan motor faultE6
Outdoor temp. sensorE7
Exhaust temp. sensorE8
IPM drive and module faultE9
Outdoor fan motor fault (DC motor)EF
Current sensor faultEA
Indoor unit EEPROM faultEE
Temp. switch fault (on top of the compressor)EP
Voltage sensor faultEU
CodeLED Indicator StatusProtection Description
P1RUN: Blink; TIMER: 1 blink / 8 secOver-voltage / under-voltage protection
P2RUN: Blink; TIMER: 2 blink / 8 secOver-current protection
P4RUN: Blink; TIMER: 4 blink / 8 secExhaust over-temperature protection
P5RUN: Bright; TIMER: 5 blink / 8 secSub-cooling protection under cooling mode
P6RUN: Bright; TIMER: 6 blink / 8 secOverheating protection under cooling mode
P7RUN: Bright; TIMER: 7 blink / 8 secOverheating protection under heating mode
P8RUN: Bright; TIMER: 8 blink / 8 secOutdoor over-temperature/ under-temperature protection
P9RUN: Blink; TIMER: 9 blink / 8 secIntelligent Power Module protection (software control)
P0RUN: Blink; TIMER: 10 blink / 8 secIntelligent Power Module protection (hardware control)
Failure TypeError CodeRecovery
IDU PCB communication failureE0-CIAuto
ODU PCB communication failureE0-COAuto
Indoor room temperature sensor failure (IRT)E1Auto
Indoor coil temperature sensor failure (IPT)E2Auto
Outdoor coil temperature sensor failure (OPT)E3Auto
AC Cooling system abnormalE4Power ON/OFF
IDU PG fan motor / DC fan motor works abnormal / failureE6Power ON/OFF
Outdoor ambient temperature sensor failureE7Auto
ODU discharge temperature sensor failureE8Auto
IPM / Compressor driving control abnormalE9Power ON/OFF
ODU DC fan motor failureEFPower ON/OFF
Abnormal Input voltage variation at time of compressor ON.EUPower ON/OFF
ODU inrush current bypass relay failureF0Power ON/OFF
Compressor Rotor blockF1Power ON/OFF
Vac abnormal (Vac>325 or Vac<125 for 5 min)F4Power ON/OFF
PFC protectionF5Auto
a. Compressor Lack of phase
b. Flux out of range
F6Power ON/OFF
IPM module temperature protectionF7Auto
Protection TypeProtection Code
IPM module protectionP0
Over and under voltage protectionP1
Over current protectionP2
ODU discharge over temperature protectionP4
IDU coil low temperature protectionP5
ODU coil over temperature protection in cool modeP6
ODU ambient over & under temperature protectionP8
Compressor driving protection (Load abnormal)P9
SymbolParameter DescriptionTechnical Short-form
H1IDU Room Temp SensorTr
H2IDU Coil Temp SensorTe
H3ODU Ambient tempTa
H4ODU Condenser tempTc
H5ODU Discharge tempTd
H6ODU AC Input CurrentIac
H7ODU DC compressor phase currentIdc
H8ODU DC Bus VoltageVdc
H9Compressor frequencyHz
HPODU IPM temp Sensor readingTipm
HUODU Suction temp Sensor readingTsu