BPL Split Inverter AC Error Code List

ErrorMeaning
EEIndoor machine EE fault
E1Indoor fan fault
E2Indoor fan zero-crossing detection abnormal
E3Indoor coil fault and sensor fault
E4Indoor ambient temperature sensor fault
E0Outdoor EE fault
E6Indoor and outdoor machine communication fault
F1Compressor starting abnormal
(phase failure,reverse)
F2Compressor out-of-step fault
F3IPM module fault
F4Compressor shell roof fault/protection
F5Discharge temperature sensor fault
F6Suction temperature sensor fault
F7Outdoor coil temperature sensor fault
F8Outdoor ambient temperature sensor fault
F9Outdoor DC fan fault
E8Outdoor communication fault
P1Outdoor machine AC current protection
P2Compressor phase current protection
P3Outdoor unit over-high/over-low AC voltage protection
P4DC voltage over-high or over-low voltage protection
P5IPM over-high temperature protection
P6Discharge temperature overheat protection
P7Cooling indoor coil anti-freezing protection
P8Cooling outdoor coil overheat at protection
P9Heating indoor coil overheat protection
PCCooling outdoor ambient temperature over-low
protection
PHHeating outdoor ambient temperature over-high
protection
PbPFC software over-current Error
PdPFC hardware over current protection(PFC Fo)
L1Drive bus voltage over-high protection
L2Drive bus voltage over-low protection
L3Drive phase current overload fault
L4Phase current sampling abnormal

Sources: