Voltas Split AC All Error Code List

ErrorMeaning
EEIndoor machine EE fault
E1Indoor fan fault
E2Indoor fan zero-crossing detection abnormal
E3Indoor coil fault and sensor fault
E4Indoor ambient temperature sensor fault
E0Outdoor EE fault
E6Indoor and outdoor machine communication fault
F1Compressor starting abnormal
(phase failure,reverse)
F2Compressor out-of-step fault
F3IPM module fault
F4Compressor shell roof fault/protection
F5Discharge temperature sensor fault
F6Suction temperature sensor fault
F7Outdoor coil temperature sensor fault
F8Outdoor ambient temperature sensor fault
F9Outdoor DC fan fault
E8Outdoor communication fault
P1Outdoor machine AC current protection
P2Compressor phase current protection
P3Outdoor unit over-high/over-low AC voltage protection
P4DC voltage over-high or over-low voltage protection
P5IPM over-high temperature protection
P6Discharge temperature overheat protection
P7Cooling indoor coil anti-freezing protection
P8Cooling outdoor coil overheat at protection
P9Heating indoor coil overheat protection
PCCooling outdoor ambient temperature over-low
protection
PHHeating outdoor ambient temperature over-high
protection
PbPFC software over-current Error
PdPFC hardware over current protection(PFC Fo)
L1Drive bus voltage over-high protection
L2Drive bus voltage over-low protection
L3Drive phase current overload fault
L4Phase current sampling abnormal
ERRORBLINKMEANING
E025 TimesIndoor unit EEPROM parameter error
E227 TimesZero-crossing signal detection error
E326 TimesThe Indoor fan speed iSoperating outside
the normal range
E429 TimesIndoor room temperature sensor is open
circuit or short circu
E528 TimesEvaporator coll temperature sensor is open
circuit or short circuit
EC30 TimesRefrigerant leakage detected
E12 TimesIndoor/outdoor units communication error
F111 TimesOutdoor ambient temperature sensor is
open circuit or short circuit
F210 TimesCondenser coil temperature sensor is
open circuit or short circuit
F38 TimesCompressor Compressor discharge discharge tempe teper
F41 TimesOutdoor unit EEPROM parameter error
F512 TimesOutdoor DC fan motor fault
F89 TimesCompressor Suction temperature sensor
fault
L333 TimesDrive phase current overload fault
L434 TimesPhase current sampling fault
P06 TimesIPM module fault
P27 TimesCompressor shell temperature overheat
protection
P44 TimesCompressor starting abnormal
F05 TimesCompressor out-of-step abnormal
L113 TimesOutdoor AC current protection
L231 TimesDrive bus voltage overload protection
P115 TimesDrive bus voltage over-low protection
P514 TimesOutdoor Over-high/Over-low AC voltage
protection
P616 TimesCompressor phase current protection
P717 TimesOutdoor Over-high/Over-low DC voltage protection
P818 TimesCOMPRESSOR DISCHARGE TEMPERATURE OVERHEAT PROTECTION
P919 TimesCOOLING INDOOR UNIT ANTI-FREEZING PROTECTION
PU20 TimesCOOLING OUTDOOR COIL OVERHEAT PROTECTION
PE21 TimesHEATING INDOOR COIL OVERHEAT PROTECTION
PC22 TimesCOLLING OUTDOOR AMBIENT TEMPERATURE OVER-LOW PROTECTION
PH23 TimesHEATING OUTDOOR AMBIENT TEMPERATURE OVER-HIGH PROTECTION